Industrial Radial Backward Fans
YVQ/N Series

  • Range

    V (m³/h) = 670÷255000
    Pt (kg/m²) = 72÷900

  • Features

    Low and medium pressure fans radial flow.
    High-efficiency low-noise backward blades impeller.
    Direct-coupled motor with impeller splined on the shaft or Belt drive transmission.

  • Temperature

    Temperature allowed:

    • Direct-coupled: Maximum fluid temperature allowed is 80°C or 150 °C if a cooling fan is installed
    • Belt Drive: Maximum fluid temperature allowed is 90°C or 350°C if a cooling fan is installed

    In case of higher temperatures, some modifications to the fan structure are needed.

  • Typical Applications

    This type of fan is suitable to suck very dusty air with suspended material (dust or granulates). NO filaments.

    • Fumes/gas elimination
    • Small shavings suction
    • Sawings handling
    • Burr suction
    • Grinding suction
    • Mechanical draught
    • Granulate handling
    • Flour and powder handling
    • NO filaments

    For further details please contact our technical department.

  • Cooling fan
  • Custom painting
  • Drain cap
  • Inspection door
  • Special steel manufacturing
  • Dampers
  • Inhibitor treatment
  • Special Belt/shaft guard
  • Manufactured in compliance with ATEX directive
Cement-Industry-Electric-Motors-Industrial-Fan-Blowers Stiavelli
Steel Industry

Presale Data

You can count on updated documentation, technical data and data sheets. Drawings and 3D rendering available for all the models.

Documentation

Our Fans and Blowers are tighter with our responsive Instruction and Maintenance Manual available in multilingual version.

Safe Packaging

The proper solution for transport and storage. It complies with worldwide regulations providing precautions for corrosion, vibrations and shocks.